  1. switch back to native mode to restart fcdomain

  2. can't use lun zoning, broadcast zoning or zone based QoS

  3. FICON and interop modes are mutually exclusive

  4. interop 1 doesn't support "zoneset distr v vsan"

  5. interop 2 E ports require fcrxbbcredits set to 16 to talk correctly with Brocade switches

  6. When using interop mode 4 you must change vsan-wwn to follow the format of: 2y:yy:08:00:88:xx:xx:xx

  7. y:yy = the VSAN in hex your working with

  8. x = last 3 bytes of actual switch wwn

  9. interop 4 offsets domains by 96, so when you configure domain 3, its going to have FCID's of 0x63xxxx.